Транскутантний вплив лазерного випромінювання на величину сатурації венозної крові киснем

Автор(и)

  • O. Ostapenko V.G. Bar’yakhtar Institute of Magnetism, Nat. Acad. of Sci. of Ukraine https://orcid.org/0009-0002-3670-2955
  • O. Salyuk V.G. Bar’yakhtar Institute of Magnetism, Nat. Acad. of Sci. of Ukraine, National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”
  • D. Velyhotskyi V.G. Bar’yakhtar Institute of Magnetism, Nat. Acad. of Sci. of Ukraine, National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute” https://orcid.org/0000-0003-1261-9428
  • S. Mamilov V.G. Bar’yakhtar Institute of Magnetism, Nat. Acad. of Sci. of Ukraine https://orcid.org/0000-0002-0175-7019

DOI:

https://doi.org/10.15407/ujpe70.5.333

Ключові слова:

оксигемоглобiн, венозна сатурацiя, фотодисоцiацiя, лазер, артерiальна сатурацiя

Анотація

Робота присвячена визначенню впливу зовнiшнього черезшкiрного лазерного випромiнювання на вiдносну концентрацiю оксигемоглобiну в венознiй кровi. Показано, що при черезшкiрному лазерному опромiнюваннi бiологiчної кровонаповненної тканини змiна величини сатурацiї венозної кровi киснем спостерiгається тiльки при досягненнi певного рiвня лазерностимульованої фотодисоцiацiї оксигемоглобiну в артерiальнiй кровi (зменшення величини сатурацiї артерiальної кровi киснем бiльш нiж на 6%). На нашу думку, цей процес не є безпосередньою лазерностимульованою фотодисоцiацiєю оксигемоглобiну в венознiй кровi, оскiльки крива дисоцiацiї знаходиться в областi високих значень парцiального тиску кисню. Зменшення вiдносної концентрацiї оксигемоглобiну у венознiй кровi скорiш за все пов’язано з компенсаторними механiзмами гiпоксiї периферичних тканин з врахуванням рекомбiнацiї молекул оксигемоглобiну на шляху вiд точки опромiнювання до точки екстракцiї кисню клiтинами.

Посилання

1. Q. Gibson, S. Ainsworth. Photosensitivity of hæm compounds. Nature 180, 1416 (1957).

https://doi.org/10.1038/1801416b0

2. V. Mansouri, B. Arjmand, M. Rezaei Tavirani, M. Razzaghi, M. Rostami-Nejad, M. Hamdieh. Evaluation of efficacy of low-level laser therapy. J. Lasers Med Sci. 11, 369 (2020).

https://doi.org/10.34172/jlms.2020.60

3. B. Arjmand, M. Khodadost, S. Jahani Sherafat, M. Rezaei Tavirani, N. Ahmadi, M. Hamzeloo Moghadam, F. Okhovatian, S. Rezaei Tavirani, M. Rostami-Nejad. Low-level laser therapy: Potential and complications. J. Lasers Med. Sci. 4, e42 (2021).

https://doi.org/10.34172/jlms.2021.42

4. M. Cecconi, D. De Backer, M. Antonelli, R. Beale, J. Bakker, C. Hofer et al. Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of intensive care medicine. Intensiv Care Med. 40, 1795 (2014).

https://doi.org/10.1007/s00134-014-3525-z

5. C. Hartog, F. Bloos. Venous oxygen saturation. Best Practice & Research Clinical Anaesthesiology 28, 419 (2014).

https://doi.org/10.1016/j.bpa.2014.09.006

6. R.S. Loomba, J. Rausa, D. Sheikholeslami, A. Dyson, Farias, E.G. Villarreeal et al. Correlation of near-infrared spectroscopy oximetry and corresponding venous oxygen saturations in children with congenital heart disease. Pediatr Cardiol 43, 197 (2022).

https://doi.org/10.1007/s00246-021-02718-7

7. G. Khirfan, A. Almoushref, T. Naal, B. Abuhalimeh, R.A. Dweik, G.A. Heresi et al. Mixed venous oxygen saturation is a better prognosticator than cardiac index in pulmonary arterial hypertension. Chest. 158, 2546 (2020).

https://doi.org/10.1016/j.chest.2020.06.053

8. D. Altun, A. Do˘gan, A. Arnaz, A. Y¨uksek, Y.K. Yal¸cinba¸s, R. T¨urk¨oz et al. Noninvasive monitoring of central venous oxygen saturation by jugular transcutaneous near-infrared spectroscopy in pediatric patients undergoing congenital cardiac surgery. Turkish J. Medical Sci. 50 (5), 12 (2020).

https://doi.org/10.3906/sag-1911-135

9. S. Chetana Shanmukhappa, S. Lokeshwaran. Venous Oxygen Saturation (StatPearls Publishing, 2023).

10. S.S. Yesman, S.O. Mamilov, D.V. Veligotsky, A.I. Gisbrecht. Local changes in arterial oxygen saturation induced by visible and near infrared light radiation. Lasers in Med. Sci. 31, 145 (2016).

https://doi.org/10.1007/s10103-015-1838-y

11. M. Wolf, G. Duc, M. Keel, P. Niederer. Continuous noninvasive measurement of cerebral arterial and venous oxygen saturation at the bedside in mechanically ventilated neonates. Crit. Care Med. 9, 1579 (1997).

https://doi.org/10.1097/00003246-199709000-00028

12. R. Sudy, F. Petak, A. Schranc, S. Agocs, I. Blaskovics, C. Lengyel et al. Differences between central venous and cerebral tissue oxygen saturation in anaesthetised patients with diabetes mellitus. Sci. Rep. 9, 19740 (2019).

https://doi.org/10.1038/s41598-019-56221-4

13. M.A. Franceschini, A. Zourabian, J.B. Moore, A. Arora, S. Fantini, D.A. Boas. Local measurement of venous saturation in tissue with non-invasive, near-infrared respiratory-oximetry. Proc. SPIE. 4250, 164 (2001).

https://doi.org/10.1117/12.434535

14. S. Dech, F. Bittmann, L. Schaefer. Behavior of oxygen saturation and blood filling in the venous capillary system of the biceps brachii muscle during a fatiguing isometric action. Eur. J. Transl. Myol. 30, 8800 (2020).

https://doi.org/10.4081/ejtm.2019.8800

15. A. Svedmyr, M. Konrad, M. Wallin, M. Hallback, Lonnqvist, Karlsson. Non-invasive capnodynamic mixed venous oxygen saturation during major changes in oxygen delivery. J. Clin Monit Comput. 36, 1315 (2022).

https://doi.org/10.1007/s10877-021-00762-5

16. M. Iliukha, S. Mamilov, D. Velyhotskyi, I. Bekh, O. Strykun. Software and hardware implementation of current monitoring methods on changes in the health status of carbon monoxide poisoned. In: International Conference on e-Health and Bioengineering (EHB 2021) (IEEE, 2021), p. 151 [ISBN: 978-1-6654-4001-1].

https://doi.org/10.1109/EHB52898.2021.9657688

17. M.A. Franceschini, D.A. Boas, A. Zourabian, S.G. Diamond, S. Nadgir, D.W. Lin et al. Near-infrared spiroximetry: Noninvasive measurements of venous saturation in piglets and human subjects. J. Appl. Physiol. 92, 372 (2002).

https://doi.org/10.1152/jappl.2002.92.1.372

18. S.S. Yesman, S.A. Mamilov, M.M. Asimov, A.I. Gisbreht. Noninvasive methods of measuring oxygen saturation in venous blood. J. Appl. Spectroscopy 78, 406 (2011).

https://doi.org/10.1007/s10812-011-9473-2

19. K. Falahati, H. Tamura, I. Burghardt, M. Huix-Rotllant. Ultrafast carbon monoxide photolysis and heme spin-crossover in myoglobin via nonadiabatic quantum dynamics. Nature Communications 9, 4502 (2018).

https://doi.org/10.1038/s41467-018-06615-1

##submission.downloads##

Опубліковано

2025-06-04

Як цитувати

Ostapenko, O., Salyuk, O., Velyhotskyi, D., & Mamilov, S. (2025). Транскутантний вплив лазерного випромінювання на величину сатурації венозної крові киснем. Український фізичний журнал, 70(5), 333. https://doi.org/10.15407/ujpe70.5.333

Номер

Розділ

Фізика рідин та рідинних систем, біофізика і медична фізика

Схожі статті