Моніторинг перебігу ферментативних реакцій методом диференціальної мікрохвильової діелектрометрії в реальному часі

Автор(и)

  • K.S. Kuznetsova O.Ya. Usykov Institute for Radiophysics and Electronics, Nat. Acad. of Sci. of Ukraine
  • V.A. Pashynska O.Ya. Usykov Institute for Radiophysics and Electronics, Nat. Acad. of Sci. of Ukraine, B. Verkin Institute for Low Temperature Physics and Engineering, Nat. Acad. of Sci. of Ukraine
  • Z.E. Eremenko O.Ya. Usykov Institute for Radiophysics and Electronics, Nat. Acad. of Sci. of Ukraine, Leibniz Institute for Solid State and Materials Research (Dresden, Germany)
  • O.I. Shubnyi O.Ya. Usykov Institute for Radiophysics and Electronics, Nat. Acad. of Sci. of Ukraine
  • A.V. Martynov Mechnikov Institute of Microbiology and Immunology, Nat. Acad. of Med. Sci. of Ukraine
  • A.A. Prokopenko Kharkiv National Automobile and Highway University

DOI:

https://doi.org/10.15407/ujpe68.9.608

Ключові слова:

рiдини з великими втратами, комплексна дiелектрична проникнiсть, ферментативнi реакцiї, поширення електромагнiтних хвиль, диференцiальна мiкрохвильова дiелектрометрiя, фермент трипсин, сироватковий альбумiн людини, iмуноглобулiн G

Анотація

Ферментативнi реакцiї є основою багатьох бiотехнологiчних виробничих i бiомедичних дiагностичних процедур, якi потребують ефективних методiв контролю за ходом реакцiї. У данiй роботi представленi результати розробки нового пiдходу методу диференцiальної дiелектрометрiї для неiнвазивного монiторингу перебiгу ферментативних реакцiй на основi комплексних змiн дiелектричної проникностi цих розчинiв реакцiйної сумiшi в реальному часi на фiксованiй частотi 31,82 ГГц. Проведено динамiчнi дослiдження дiелектричних параметрiв видiлених ферментативних систем, що мiстять бiлковий субстрат (iмуноглобулiн G, сироватковий альбумiн людини) та фермент трипсин. Запропоновано застосування розробленої вимiрювальної комiрки мiкрохвильового диференцiйного дiелектрометру для монiторингу ферментативних реакцiй у бiомедичнiй практицi та харчовiй промисловостi. Нашi результати мiкрохвильової дiелектрометрiї пiдтверджено результатами методу спектрофотометрiї UV-Vis для вибраних ферментативних систем. Ми пропонуємо новий пiдхiд до використання методу дiелектрометрiї з високою чутливiстю (2,7 та 1% для дiйсної та уявної частин комплексної дiелектричної проникностi, вiдповiдно) для оцiнки перебiгу ферментативних реакцiй у реальному часi.

Посилання

G.D. Najafpour. Biochemical Engineering and Biotechnology (Elsevier, 2015) [ISBN: 978-0-444-63357-6].

https://doi.org/10.1016/B978-0-444-63357-6.00002-X

K.S. Siddiqui, H. Ertan, A. Poljak, W.J. Bridge. Evaluating enzymatic productivity-the missing link to enzyme utility. Int. J. Mol. Sci. 23 (13), 6908 (2022).

https://doi.org/10.3390/ijms23136908

M. Faure, M. Kechadi, B. Sotta, J. Gamby, B. Tribolleta. Contact free impedance methodology for investigating enzymatic reactions into dielectric polymer microchip. Electroanalysis 25 (5), 1151 (2013).

https://doi.org/10.1002/elan.201200488

Y. Iwasaki, T. Horiuchi, O. Niwa. Detection of electrochemical enzymatic reactions by surface plasmon resonance measurement. Anal. Chem. 73 (7), 1595 (2001).

https://doi.org/10.1021/ac0012851

A. Furukawa, T. Nagata, A. Matsugami, Y. Habu, R. Sugiyama, F. Hayashi, N. Kobayashi, S. Yokoyama, H. Takaku, M. Katahira. Structure, interaction and realtime monitoring of the enzymatic reaction of wild-type APOBEC3G. The EMBO J. 28 (4), 440 (2009).

https://doi.org/10.1038/emboj.2008.290

F. C. Church, H. E. Swaisgood, D.H. Porter, G.L. Cattignani. Spectrophotometric assay using o-phthaldialdehyde for determination of proteolysis in milk and isolated milk proteins. J. Dairy Sci. 66, 1219 (1983).

https://doi.org/10.3168/jds.S0022-0302(83)81926-2

W.J. Ellison, K. Lamkaourchi, M.J. Moreau. Water: A dielectric reference. J. Mol. Liq. 68, 171 (1996).

https://doi.org/10.1016/0167-7322(96)00926-9

A. Godio. Open ended-coaxial cable measurements of saturated sandy soils. American J. Environmental Sci. 3 (3), 175 (2007).

https://doi.org/10.3844/ajessp.2007.175.182

J. M. McKee, B.P. Johnson. Real-time chemical sensing of aqueous ethanol glucose mixtures. IEEE Transactions on Instrumentation and Measurement 49 (1), 114 (2000).

https://doi.org/10.1109/19.836320

I. Dilman, M. N. Akinci, T. Yilmaz, M. ¸Cay¨oren, I. Akduman. A method to measure complex dielectric permittivity with open-ended coaxial probes. IEEE Transactions on Instrumentation and Measurement 71, (2022).

https://doi.org/10.1109/TIM.2022.3147878

Keysight Technologies, Keysight n1501a Dielectric Probe Kit 200 MHz to 50 GHz. 2021. [Online]. Available: http://literature.cdn.keysight.com/litweb/pdf/5989-0222EN.pdf.

F. Artis, T. Chen, T. Chretiennot, J.-J. Fournie, M. Poupot, D. Dubuc, K. Grenier. Microwaving biological cells: intracellular analysis with microwave dielectric spectroscopy. IEEE Microwave Magazine 16 (4), 87 (2015).

https://doi.org/10.1109/MMM.2015.2393997

K. Shibata. Measurement of complex permittivity for liquid materials using the open-ended cut-off waveguide reflection method. IEICE Transactions on Electronics E93-C (11), 1621 (2010).

https://doi.org/10.1587/transele.E93.C.1621

Y. Wang, M.N. Afsar. Measurement of complex permittivity of liquids using waveguide techniques. Progress in Electromagnetics Research 42, 131 (2003).

https://doi.org/10.2528/PIER03010602

J. Barthel, K. Bachhuber, R. Buchner, H. Hetzenauer. Dielectric spectra of some common solvents in the microwave region. Water and lower alcohols. Chem. Phys. Lett. 165 (4), 369 (1990).

https://doi.org/10.1016/0009-2614(90)87204-5

Z.E. Eremenko, K.S. Kuznetsova, N.I. Sklyar, A.V. Martynov. Measuring Complex Permittivity of High-Loss Liquids in Dielectric Materials and Applications. Edited by P.G. Choudhry (Nova Science Publishers, 2019), Chap. 2 [ISBN: 978-1-53615-316-3].

Z.E. Eremenko, V.N. Skresanov, A.I. Shubnyi, N.S. Anikina, V.G. Gerzhikova, T.A. Zhilyakova. Complex Permittivity Measurement of High Loss Liquids and its Application to Wine Analysis in Electromagnetic Waves. Edited by V. Zhurbenko (Janeza Trdine, 2011) [ISBN: 978-953-307-304-0].

https://doi.org/10.5772/17748

Z.E. Eremenko, V.A. Pashynska, K.S. Kuznetsova, O.I. Shubnyi, N.I. Sklyar, A.V. Martynov. Microwave dielectrometer application to antibiotic concentration control in water solution. Low Temperature Physics 26, (3), 30 (2021).

https://doi.org/10.15407/rej2021.03.030

V.N. Skresanov, Z.E. Eremenko, E.S. Kuznetsova, Y. Wu, Y. He. Circular layered waveguide use for wideband complex permittivity measurement of lossy liquids. IEEE Transactions on Instrumentation and Measurement 63 (3), 694 (2014).

https://doi.org/10.1109/TIM.2013.2282003

S. Schmidt, M. Schubler. All Liquid Based Calibration Scheme for Microwave Dielectrometry. In Proceedings IEEE/MTT-S International Microwave Symposium USA, 8058839 (2017).

https://doi.org/10.1109/MWSYM.2017.8058839

A.A. Abduljabar, D.J. Rowe, A. Porch, D.A. Barrow. Novel microwave microfluidic sensor using a microstrip split-ring resonator. IEEE Transactions on Microwave Theory and Techniques 62 (3), 679 (2014).

https://doi.org/10.1109/TMTT.2014.2300066

A.I. Gubin, A.A. Barannik, N.T. Cherpak, I.A. Protsenko, S. Pud, A. Offenh¨ausser, S.A. Vitusevich. Whisperinggallery-mode resonator technique with microfluidic channel for permittivity measurement of liquids. IEEE Transactions on Microwave Theory and Techniques 63 (6), 2003 (2015).

https://doi.org/10.1109/TMTT.2015.2423289

J.-W.C. Alffenaar, E.M. Jongedijk, C.A.J. van Winkel, M. Sariko, S.K. Heysell, S. Mpagama, D.J. Touw. A mobile microvolume UV/visible light spectrophotometer for the measurement of levofloxacin in saliva. J. Antimicrobial Chemotherapy 76 (2), 423 (2021).

https://doi.org/10.1093/jac/dkaa420

Huffman, K. Soni, J. Ferraiolo. UV-Vis based determination of protein concentration: validating and implementing slope measurements using variable pathlength technology. BioProcess International 12 (8), (2014).

Downloads

Опубліковано

2023-10-20

Як цитувати

Kuznetsova, K., Pashynska, V., Eremenko, Z., Shubnyi, O., Martynov, A., & Prokopenko, A. (2023). Моніторинг перебігу ферментативних реакцій методом диференціальної мікрохвильової діелектрометрії в реальному часі. Український фізичний журнал, 68(9), 608. https://doi.org/10.15407/ujpe68.9.608

Номер

Розділ

Фізика рідин та рідинних систем, біофізика і медична фізика